High Sensitivity Turbidity Analyzer TUH-1600 Highly-sensitive turbidity analyzer suitable for water purification process Surface scattering light method employed; 1 range/2 ranges/3 ranges available RS-485 equipped as standard specification; compatible with Modbus communication system Freely mountable on walls, racks, etc. for the compact lightweight design Meas. range 0 - 0.2 to 0 - 2.0 (1 - 3 ranges) (NTU)
Suitable for water purification process (including river water, etc.) Surface scattering light method employed; 1 range/2 ranges/3 ranges available Reduces flow volume of sample water to 1/2 of existing models RS-485 equipped as standard specification; compatible with Modbus communication system Freely mountable on walls, racks, etc. for the compact lightweight design Meas. range 0 - 2 to 0 - 2000 (1 - 3 ranges) (mg/L, ppm, FTU, NTU)
Continuous optical measurements of SS and MLSS by using infrared scattering method Safe and simple maintenance attainable with the small, lightweight stainless detector Meas. range 0 - 1000/3000 mg/L 0 - 10000/20000/30000 mg/L (2-ranges or 3-ranges)
Compact and piston automated analyzer Types of detectors available: immersion, drop-in and pipe insertion Long-life optical model and high reliability RS-485 interface equipped as standard specification; compatible with Modbus communication system Meas. range SSD-1610: 0 - 30/500/1000 mg/L SSD-1620: 0 - 5000/10000/20000 mg/L (3-range, manual switching)
Continuous measurement of alkalinity data in water purification process by coulometric titration method Requires only 1/4 reagent volume of existing model RS-485 equipped as standard specification; compatible with Modbus communication system Freely mountable on walls, racks, etc. for the compact lightweight design Meas. range 0 - 50/100 mg/L (ppm) (2-ranges)
The cleaning process done by two filters alternately allows for continuous supply of sample Filtration rate 1 - 6 L/min (Varies from sample turbidity)
A complete sampling system composed with cooler, pressure reducer, valves, flowmeter and thermostat chambers Enables sampling for analysis from the boiler Consistent manufacturing from analyzer to sampler Sample condition Maximum temperature: 600 degrees C Maximum pressure: 30 MPa Maximum flow rate: 3 L/min
Continuous measurement of hydrazine concentration in boiler water Stabilization determination function during calibration Best suited for monitoring of residual hydrazine concentration Meas. range 0 - 999.9 μg/L